Drain/Waste vent systems (DWV) systems maintain air pressure in the drain lines, allowing flow of water and sewage down drain lines and through waste pipes using good ol’ gravity. It’s important that a downward slope be maintained throughout, to keep liquids and solids flowing freely towards the main drain from the building. In rare situations, a downward slope out of a building to the sewer can’t be created, and a special collection pit and grinding lift "sewage ejector" pump is needed. By contrast, drinking water supply systems operate under pressure to distribute water up through buildings, and do not require a continuous downward slope in their piping. Every fixture is required to have an internal or external trap; double trapping is prohibited by current plumbing codes due to its susceptibility to clogging. Every plumbing fixture must also have an attached vent. The top of stacks must be vented too, via a stack vent, which is sometimes called a stink pipe. All plumbing waste fixtures use traps to prevent sewer gases from leaking into the house. Through traps, all fixtures are connected to waste lines, which in turn take the waste to a "soil stack", or "soil vent pipe". At the building drain system's lowest point, the drain-waste vent is attached, and rises (usually inside a wall) to and out of the roof. Waste exits from the building through the building's main drain and flows through a sewage line, which leads to a septic system or a public sewer. Cesspools are generally prohibited in developed areas. The venting system, or plumbing vents, consists of a number of pipes leading from waste pipes to the outdoors, usually through the roof. Vents provide a means to release sewer gases outside instead of inside the house. Vents also admit oxygen to the waste system to allow aerobic sewage digestion, and to discourage noxious anaerobic expansion. Vents provide a way to equalize the pressure on both sides of a trap, thereby allowing the trap to hold the water which is needed to maintain effectiveness of the trap, and avoiding "trap suckout" which otherwise might occur. A sewer pipe is normally at neutral air pressure compared to the surrounding area. When a column of waste water flows through a pipe, it compresses air ahead of it in the pipe, creating a positive pressure that must be released so it does not push back on the waste stream and downstream trap water seals. As the column of water passes, air must freely flow in behind the waste stream, or negative pressure results. The extent of these pressure fluctuations is determined by the fluid volume of the waste discharge.Excessive negative air pressure, behind a "slug" of water that is draining, can siphon water from traps at plumbing fixtures. Generally, a toilet outlet has the shortest trap seal, making it most vulnerable to being emptied by induced siphonage. An empty trap can allow noxious sewer gases to enter a building.On the other hand, if the air pressure within the drain becomes suddenly higher than ambient, this positive transient could cause waste water to be pushed into the fixture, breaking the trap seal, with serious hygeine and health consequences if too forceful. Taller buildings of three or more stories are particularly susceptible to this problem. Vent stacks are installed in parallel to waste stacks to allow proper venting in tall buildings.Most residential building drainage systems in North America are vented directly through the building roofs. The DWV pipe is typically ABS or PVC DWV-rated plastic pipe equipped with a flashing at the roof penetration to prevent rainwater from entering the buildings. Older homes may use Cast iron or lead pipes.Under many older building codes, a vent stack (a pipe leading to the main roof vent) is required to be within a 5-foot (1.5 m) radius of the draining fixture it serves (sink, toilet, shower stall, etc.). To allow only one vent stack, and thus one roof penetration as permitted by local building code, sub-vents may be tied together inside the building and exit via a common vent stack. One additional requirement for a vent stack connection occurs when there are very long horizontal drain runs with very little slope to the run. Adding a vent connection within the run will aid flow, and when used with a cleanout allows for better serviceability of the long run.A blocked vent is a relatively common problem caused by anything from leaves, to dead animals, to ice dams in very cold weather, or a horizontal section of the venting system, sloped the wrong way and filled with water from rain or condensation. Symptoms range from bubbles in the toilet bowl when it is flushed, to slow drainage, and all the way to siphoned (empty) traps which allow sewer gases to enter the building.When a fixture trap is venting properly, a "sucking" sound can often be heard as the fixture vigorously empties out during normal operation. This phenomenon is harmless, and is different from "trap suckout" induced by pressure variations caused by wastewater movement elsewhere in the system, which is not supposed to allow interactions from one fixture to another. Toilets are a special case, since they are usually designed to self-siphon to ensure complete evacuation of their contents; they are then automatically refilled by a special valve mechanism.An island fixture vent, sometimes colloquially called a "Chicago Loop" is an alternate way of venting the trap installed on an under counter island sink or other similar applications where a conventional vertical vent stack or air admittance valve (AAV) is not feasible or allowed.As with all drains, ventilation must be provided to allow the flowing waste water to displace the sewer gas in the drain, and then to allow air (or some other fluid) to fill the vacuum which would otherwise form as the water flows down the pipe.An island fixture vent provides an elegant solution for this necessity: when the drain is opened, water displaces the sewer gas up to the sanitary tee, the water flows downward while sewer gas is displaced upward and toward the vent. The vent can also provide air to fill any vacuum created.The key to a functional island fixture vent is that the top elbow must be at least as high as the "flood level" (the peak possible drain water level in the sink). This ensures that the vent never becomes waterlogged. Like to learn more about your home and how it all works? Check back here often for great content.
2 Comments
It's interesting to know that there should be no interactions from different fixtures when it comes to wastewater movement. In that case, it is a good idea to have a proper wastewater flow control system in place to prevent issues. I will make sure that I mention this to the contractors that I will hire once my dream house is going to be built next year.
Reply
I never took into account the fact that there are different fluctuations in the system when there are pressure changes depending on the fluid volume of the water discharge. In that case, it is important to hire professionals from a residential lift station to check a property every now and then. In my opinion, it is better to be ready and prevent issues from happening than fixing them, especially when you are on a limited budget.
Reply
Your comment will be posted after it is approved.
Leave a Reply. |
AuthorCale Cameron Archives
October 2024
Categories |